LAQUA K-11/CA-11/NO3-11/NA-11

Share:


LAQUA K-11/CA-11/NO3-11/NA-11

Contact Us
Izah
: +6018-236 7662
: ecc17info@gmail.com

Potassium Ion
Model: K-11
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 mL (0.05 mL with Sampling Sheet B)
Measurement Range: 4 to 9900 ppm (mg/L)
(0.1 to 250 mmol/L)
2 to 5000 kg/10a (soil/water ratio 1:5)
Resolution: 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm 
1000 to 9900 ppm: 100 ppm
Accuracy Maximum: ±10% of actual value
Calibration Points: 2
Accessories Included:
150 & 2000 ppm Standard Solutions (14 mL each)
  • Sampling Sheet B (5 pcs)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals
  • Storage Case
 
Calcium Ion
Model: Ca-11
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 mL (0.05 mL with Sampling Sheet B)
Measurement Range: 4 to 9900 ppm (mg/L)
(0.1 to 250 mmol/L)
Resolution: 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm 
1000 to 9900 ppm: 100 ppm
Accuracy Maximum: ±20% of actual value
Calibration Points: 2
Accessories Included:
150 & 2000 ppm Standard Solutions (14 mL each)
  • Sampling Sheet B (5 pcs)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals
  • Storage Case
 
Sodium Ion
Model: Na-11
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 mL (0.05 mL with Sampling Sheet B)
Measurement Range: 2 to 9900 ppm (mg/L)
(0.1 to 430 mmol/L)
Resolution: 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm 
1000 to 9900 ppm: 100 ppm
Accuracy Maximum: ±10% of actual value
Calibration Points: 2
Accessories Included:
150 & 2000 ppm Standard Solutions (14 mL each)
  • Sampling Sheet B (5 pcs)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals
  • Storage Case
 
Nitrate Ion
Model: NO3-11
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 mL (0.05 mL with Sampling Sheet B)
Measurement Range: NO3-: 6 to 9900 ppm (mg/L)
(0.1 to 160 mmol/L)
NO3-N: 1.4 to 2200 ppm (mg/L)
Resolution: 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm 
1000 to 9900 ppm: 100 ppm
Accuracy Maximum: ±10% of actual value
Calibration Points: 2
Accessories Included:
150 & 2000 ppm Standard Solutions (14 mL each)
  • Sampling Sheet B (5 pcs)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals
  • Storage Case

Specifications

Sorry, currently do not have any product specifications

Brewers' Pocket Meter LAQUAtwin by HORIBA

Sorry, currently do not have any file for download.
Safety Services
Environmental Services
Training
Product Sales