LAQUA


Tag Selection


Dissolved Oxygen Electrode Tips 7541 Replacement DO tip for 9520-10D

 

Dissolved Oxygen Electrode Tips 5401 Replacement DO tip for 9551-20D and 9551-100D DO electrodes

 

Dissolved Oxygen Electrodes 9520 - 10D for Laboratories Dissolved Oxygen Range: 0 to 19.


More Details...

Dissolved Oxygen Electrode 9551-100D for Field Immersible Type (10m cable) Dissolved Oxygen Range: 0 to 19.


More Details...

Dissolved Oxygen Electrode
9551 - 20D for Field Immersible Type (2m cable) Dissolved Oxygen Range: 0 to 19.


More Details...

Conductivity Cells (Flow Type) 3574-10C Cell Constant (cm-1): 10 Measurement Range: 10µS/cm to 100mS/cm Sample Volume Required (mL): 0.


More Details...

  Conductivity Cells (Flow Type) 3573-10C Cell Constant (cm-1): 10 Measurement Range: 10µS/cm to 100mS/cm Sample Volume Required (mL): 4 Temperature Sensor: --- Temperature Range: 0 to


More Details...

Conductivity Cells (Flow Type) 3574-10C Cell Constant (cm-1): 1 Measurement Range: 1µS/cm to 100mS/cm Sample Volume Required (mL): 16 Temperature Sensor: Integrated Temperature Range: 0 to


More Details...

Conductivity Cells (Flow Type) 3561-10D Cell Constant (cm-1): 0.1 Measurement Range: 0.


More Details...

Conductivity Cells (Submersible Type) 3553-10D Cell Constant (cm-1): 10 Measurement Range: 10µS/cm to 1S/cm Sample Volume Required (mL): 50 Temperature Sensor: Integrated Temperature Range: 0 to


More Details...

Conductivity Cells (Submersible Type) 3552-10D Cell Constant (cm-1): 1 Measurement Range: 1µS/cm to 100mS/cm Sample Volume Required (mL): 15 Temperature Sensor: Integrated Temperature Range: 0 to


More Details...

Conductivity Cells (Submersible Type) 3551-10D Cell Constant (cm-1): 0.1 Measurement Range: 0.


More Details...

Conductivity Cells (Submersible Type) 9382-10D Cell Constant (cm-1): 1 Measurement Range: 1µS/cm to 100mS/cm Sample Volume Required (mL): 20-30 Temperature Sensor: Integrated Temperature Range: 0 to


More Details...

LAQUA General ISFET pH electrode 0040-10D pH Range: 0 to 14 Temperature Range: 0 to 60°C Liquid Junction: Porous sintered polyethylene Temperature Sensor: Integrated Cable


More Details...

Conductivity Cells 3574-10C 3014082592 Overall Length: 136mm Diameter of Probe: 66mm Connectors: BNC Cell Constant:

  • 10cm-1
  • 1000m-1
Measurement

More Details...

ORP Electrode 9300-10D Waterproof platinum 3-in-1 type Material: Platinum (Pt), Glass body Temperature Range: 0 to 60°C Liquid Junction: Ceramic Temperature Sensor: Integrated Cable


More Details...

Conductivity Cells 3573-10C 3014082590 Overall Length: 222mm Diameter of Probe: 18mm Connectors: BNC Cell Constant:

  • 10cm-1
  • 1000m-1
Measurement

More Details...

Strong Alkali Resistant Electrode 9632-10D pH Range: 0 to 14 Temperature Range: 0 to 100°C Liquid Junction: Ceramic Temperature Sensor: Integrated Cable: 1m Connectors: BNC, phono


More Details...

Conductivity Cells 3562-10D 3014082350 Overall Length: 205mm Diameter of Probe: 18mm Connectors: BNC & phono jack Cell Constant:

  • 1cm-1
  • 100m-1
Measurement

More Details...

Gel-filled pH Electrode 9651-10D pH Range: 0 to 14 Temperature Range: 0 to 80°C Liquid Junction: Porous sintered polyethylene Temperature Sensor: Integrated Cable Length: 1m Connectors: BNC, phono


More Details...

Conductivity Cells 3561-10D 3014082350 Overall Length: 143mm Diameter of Probe: 18mm Connectors: BNC & phono jack Cell Constant:

  • 0.

More Details...

Hydroflouric Acid Resistant Electrode 9631-10D pH Range: 2 to 12 Temperature Range: 0 to 60°C Liquid Junction: Ceramic Temperature Sensor: Integrated Cable: 1m Connectors: BNC, phono


More Details...

Conductivity Cells 9382-10D 3014046709 Overall Length: 150mm Diameter of Probe: 16mm Connectors: BNC & phono jack Cell Constant:

  • 1cm-1
  • 100m-1
Measurement

More Details...

Standard Plastic Electrode 9630-10D for Tap Water pH Range: 0 to 14 Temperature Range: 0 to 100°C Liquid Junction: Ceramic Temperature Sensor: Integrated Cable: 1m Connectors: BNC, phono


More Details...

Conductivity Cells 3553-10D 3014081714 Overall Length: 175mm Diameter of Probe: 128mm Connectors: BNC & phono jack Cell Constant:

  • 10cm-1
  • 1000m-1
Measurement

More Details...

Standard Plastic Electrode
9625-10D; 9625-20D; 9625-30D for Field pH Range: 0 to 14 Temperature Range: 0 to 100°C Liquid Junction: Ceramic Temperature


More Details...

Conductivity Cells 3552-10D 3014081545 Overall Length: 150mm Diameter of Probe: 12mm Connectors: BNC & phono jack Cell Constant:

  • 1cm-1
  • 100m-1
Measurement

More Details...

Needle Electrode 6252-10D for Food Application pH Range: 0 to 12 Temperature Range (°C): 0 to 60 Liquid Junction: Ceramic Temperature Sensor: Integrated Cable: 1m Connectors: BNC, phono


More Details...

Low-Conductivity Electrode
6377-10D for Pure Water and Non-aqueous Solvents pH Range: 0 to 14 Temperature Range (°C): 0 to 60 Liquid Junction: Movable Sleeve Temperature


More Details...

Standard Sleeve Electrode
6367-10D pH Range: 0 to 14 Temperature Range (°C): 0 to 60 Liquid Junction: Sleeve Temperature Sensor: Integrated Cable: 1m Connectors: BNC, phono


More Details...

ToupH Sleeve Electrode
9681S-10D Hugh viscosity application pH Range: 0 to 14 Temperature Range (°C): 0 to 60 Liquid Junction: Movable Sleeve Temperature


More Details...

ToupH Micro Electrode
9618S-10D Precious trace amount sample pH Range: 0 to 14 Temperature Range (°C): 0 to 60 Liquid Junction: Ceramic Temperature


More Details...

ToupH Long Electrode
9680S-10D for Large Containers and Long Test Tubes pH Range: 0 to 14 Temperature Range (°C): 0 to 100 Liquid Junction: Ceramic Temperature


More Details...

Conductivity Cells
3551-10D
3014081712 Overall Length: 175mm Diameter of Probe: 23mm Connectors: BNC & phono jack Cell Constant:

  • 0.

More Details...

ORP Electrode
9300-10D
Waterproof Platinum 3 in 1 type Overall Length: 150mm Diameter of Probe: 12mm Connections: BNC & phono jack Operating Temperature Range (°C): 0 - 60 Electrode


More Details...

ToupH Standard Electrode
9615S-10D General Laboratory Application pH Range: 0 to 14 Temperature Range (°C): 0 to 100 Liquid Junction: Ceramic Temperature


More Details...

Flat Electrode
6261-10C pH Range: 0 to 12 Temperature Range (°C): 0 to 50 Liquid Junction: Sleeve Cable: 1m Connector: BNC Overall


More Details...

Potassium Ion (K+) Electrode
6582S-10C
3200697409 Overall Length: 150mm Diameter of Probe: 16mm Connector: BNC Accessories Included:

  • Potassium electrode tip, 2 pcs
  • 1000mg/L potassium ion

More Details...

Nitrate Ion (NO3-) Electrode
6581S-10C
3200697408 Overall Length: 150mm Diameter of Probe: 16mm Connector: BNC Accessories Included:

  • Nitrate electrode tip, 2 pcs
  • 1000mg/L nitrate ion

More Details...

ToupH Long Electrode
9480-10C for Large Containers and Long Test Tubes pH Range: 0 to 14 Temperature Range (°C): 0 to 100 Liquid Junction: Ceramic Cable: 1m Connector: BNC Overall


More Details...

Long Electrode
6069-10C for Very Slender pH Range: 0 to 14 Temperature Range (°C): 0 to 60 Liquid Junction: Ceramic Cable: 1m Connector: BNC Overall


More Details...

ToupH Sleeve Electrode
9481-10C High Viscosity Application pH Range: 0 to 14 Temperature Range (°C): 0 to 60 Liquid Junction: Movable Sleeve Cable: 1m Connector: BNC Overall


More Details...

ToupH Micro Electrode
9418-10C Precious Trace Amount Sample pH Range: 0 to 14 Temperature Range (°C): 0 to 60 Liquid Junction: Ceramic Cable: 1m Connector: BNC Overall


More Details...

Fluoride Ion (F-) Electrode
6561S-10C
3200693774 Overall Length: 150mm Diameter of Probe: 16mm Connector: BNC Accessories Included:

  • Fluoride electrode tip
  • 1000mg/L fluoride ion standard

More Details...

ToupH Standard Electrode
9415-10C General Laboratory Application pH Range: 0 to 14 Temperature Range (°C): 0 to 100 Liquid Junction: Ceramic Cable: 1m Connector: BNC Overall


More Details...

Standard Plastic Electrode
9425-10C General Field Application pH Range: 0 to 14 Temperature Range (°C): 0 to 100 Liquid Junction: Ceramic Cable: 1m Connector: BNC Overall


More Details...

Chloride Ion (Cl-) Electrode
6560S-10C
3200697407 Overall Length: 150mm Diameter of Probe: 16mm Connector: BNC Accessories Included:

  • Chloride electrode tip
  • 1000mg/L chloride ion standard

More Details...

Calcium Ion (Ca2+) Electrode
6583S-10C
3200697410 Overall Length: 150mm Diameter of Probe: 16mm Connector: BNC Accessories Included:

  • Calcium electrode

More Details...

Safety Services
Environmental Services
Training
Product Sales